Fixed plant

    When a pump keeps failing its mechanical seal

    When the same pump keeps going through seals, the seal is rarely the problem. NASA's maintenance guidance calls frequent seal fracture a symptom of more severe problems, and seal makers say much the same. The failed parts carry evidence of the cause, but only until they are thrown away.

    Published 6 min read7 sources

    Written for maintenance and reliability engineers · plant maintenance supervisors · fitters working on pumps in water, process and mining plant

    “When plant equipment fails repeatedly, the failures are often accepted as a normal idiosyncrasy of that equipment. Recurring problems such as short bearing life, frequent seal fracture, and structural cracking are symptoms of more severe problems.”
    NASA, Reliability-Centered Maintenance Guide for Facilities and Collateral Equipment, section 5.5.3[1]

    The guide goes on: 'Maintenance personnel often fix only the symptomatic problems and continue with the frequent repairs.'⁠[1] A mechanical seal shows why. It runs on a thin film of liquid between two faces, so it is sensitive to almost everything else about the pump: how it is run, how it is aligned, what is in the fluid, and how the seal was fitted. One seal maker's failure-analysis guide estimates that '90% of the mechanical seals in a typical plant fail due to reasons other than wearing out'. That is the manufacturer's own estimate, and the guide cites no study for it, but its next point is the useful one: the analysis 'offers clues to other equipment, system or operational deficiencies'.⁠[2]

    Where the cause usually is

    Public engineering guidance points to four places to look before blaming the seal.

    • Where the pump runs on its curve. A centrifugal pump's best efficiency point (BEP) is where 'its radial bearing loads are lowest'.⁠[3] Away from it, and especially at low flow, the radial load on the impeller rises. The Hydraulic Institute says operation 'significantly below BEP amplifies these forces, leading to increased shaft deflection, reduced bearing life, possible internal rubbing of parts or heightened vibration levels', and lists 'potential mechanical seal problems' among the effects.⁠[4] The Department of Energy's pumping sourcebook names the usual culprit: oversized pumps 'often operate far to the left of their BEP and tend to experience greater bearing and seal wear'.⁠[3]
    • Cavitation, flashing and dry running. A contact seal needs liquid between its faces. The authors of a tutorial on the API 682 seal standard explain that vapour pressure margin matters because 'contacting wet (CW) mechanical seals require liquid for cooling, lubrication, and fluid film support'.⁠[5] Cavitation in the pump itself erodes the impeller, 'accelerating the wear rate of bearings and seals in the process'.⁠[3]
    • Alignment and pipe strain. 'Many pump/motor problems are caused by pipe reactions that pull the pump out of alignment,' the sourcebook says, and because foundations and piping shift, it advises checking alignment periodically. The seal depends on the shaft running true in its chamber: 'the seal must be precisely aligned so that spring movement is minimal during each shaft revolution'.⁠[3]
    • The seal's environment and its fitting. Seal support piping plans 'describe methods of controlling the environment around the seal, conditioning the sealed fluid, collecting and controlling seal leakage, and monitoring seal performance', and the tutorial calls them 'a critical component in the successful design of a sealing system'.⁠[5] A seal's effectiveness, the sourcebook adds, is 'highly dependent on correct installation and a continuously clean operating environment'.⁠[3] A blocked flush orifice, a wrong setting dimension or an O-ring cut on a keyway will fail a new seal however well the pump is run.

    Reading the failed parts

    Seal makers publish guides that map what is seen on the faces, springs and elastomers to its likely cause. A few examples from one of them follow.⁠[2] They are starting points for an investigation, not a diagnosis, and the same mark can have more than one cause.

    • Radial cracks across the face ('heat checking'): rapid local heating, from 'loss of lubrication due to overload or vaporisation' or from running dry outside the design conditions.
    • Blisters on a carbon face: process fluid soaked into the carbon expands faster than it can escape when the face heats. 'Frequent start and stop operations will create more blisters.'
    • Chipped face edges: 'popping and slapping of faces due to flashing of process fluids', or excessive vibration.
    • A wear track wider than the face it ran against: if it is on the stationary face, 'the equipment has run out and the seal face is tracking with the shaft movement'. On pumps, the guide reads this as a problem with equipment condition or off-design operation.
    • No face wear on a failed seal: often how it was fitted, such as an 'improper seal setting dimension'.
    • Swollen elastomers: a compound 'incompatible with chemicals in the application', which the guide extends to clean-in-place and steam-in-place cycles.
    • Cut or nicked O-rings: damage at assembly over keyways and threads, or rings 'twisted or pinched during installation'.

    The pump often shows a problem before the seal does: the same guide notes that 'pump impellers often show signs of cavitation before seal components'.⁠[2] The impeller, wear rings and bearings that come out at the same job are part of the evidence too.

    What to record before the parts are thrown away

    The guide's advice on timing matters more than any table: 'Data gathering should start as soon as the work order is generated. Keep in mind, the opportunity to gather this data is lost once the equipment is removed from service.'⁠[2] Its checklist, and the form another seal maker asks customers to send back with a failed seal,⁠[6] cover much the same ground.

    • While the pump is still running: where it is leaking and how fast, where it is operating on its published curve, the condition of the seal support system or piping plan, and any piping movement or vibration.⁠[2]
    • From operations: 'whether any unit upsets, wash downs, and equipment startup or shutdown occurred prior to leakage being noted'.⁠[2]
    • From the history: how long the seal lasted, how long it ran after leakage was first seen, whether other seals have worked on the same duty, and whether anything in the system has changed. Those are headings on the return form.⁠[6]
    • At disassembly: shaft run-out, end play and radial deflection; whether the seal's compression setting was correct; whether the support piping and its orifices were clear. Photographs throughout, and 'retain the components until analysis is finalised'.⁠[2]
    • On the work order: what was found, not only 'seal replaced'. The finding is what connects this failure to the last one.

    When the pattern is the evidence

    One seal failure may be bad luck. Three on the same pump is a pattern, and the pattern often narrows the search: seals that fail after wash-downs, only since a change of duty, or on only one of two identical pumps are each pointing somewhere different. That only works if the earlier failures were recorded against the same pump, with what was found. The pump industry's life-cycle guidance makes the same point about reliability figures in general: 'Whenever available, historical data is preferable to theoretical data from the equipment supplier.'⁠[7]

    In Mainte, a technician's finding is kept as written rather than reduced to a code, findings on the same machine and component are matched so a recurrence shows as one, and photographs of the failed parts sit on the machine's timeline with the work. The fault that keeps coming back describes how that history is used. Mainte does not diagnose seal failures; that stays with the people who can hold the parts.

    Sources

    1. [1]Reliability-Centered Maintenance Guide for Facilities and Collateral Equipment · National Aeronautics and Space Administration (NASA) · September 2008 · Government maintenance guideSection 5.5.3, root-cause failure analysis.
    2. [2]Self-diagnose the root causes to your mechanical seal failure · Flexachem, distributor edition of a Flowserve guide · Undated · Manufacturer failure-analysis guideRead from a copy hosted by a third party; no copy was found on the manufacturer's own site. The 90% figure is the guide's own estimate, with no study cited.
    3. [3]Improving Pumping System Performance: A Sourcebook for Industry (second edition) · US Department of Energy and the Hydraulic Institute · May 2006 · Government technical guidance
    4. [4]Basic hydraulic loads in rotodynamic pumps · Hydraulic Institute · 7 April 2025 · Industry standards body article
    5. [5]Advancements in mechanical sealing: API 682 fourth edition · Turbomachinery Laboratory, Texas A&M University (authors from the API 682 task force) · February 2015 · Symposium tutorialAPI 682 itself is a paid standard and was not read.
    6. [6]Component seal failure information sheet (Rev 01/2017) · AESSEAL · January 2017 · Manufacturer failure return form
    7. [7]Pump Life Cycle Costs: A Guide to LCC Analysis for Pumping Systems, executive summary · Hydraulic Institute, Europump and the US Department of Energy · January 2001 · Industry and government guidance

    Bring one machine.

    Bring one machine's paperwork: the manual, the last few service reports, an inspection or two. We'll show you what Mainte does with it, and what the record looks like a year in.

    Pricing scales with the equipment you manage, not the seats you fill. hello@mainte.ai